Non-conformance & corrective action
From a failed check to a closed action
All non-conformances are invented for this demonstration and are attributed only to fictional demo delivery partners.
Open non-conformances
Scenario14
High severity
Scenario10
Scenario cost impact
ScenarioAED 25.8m
Illustrative rework and delay allowance.
Rework early warning
Where a non-conformance root cause points back to an out-of-date drawing, the same cause is likely elsewhere.
- Smoke damper installed to superseded revision C03Root cause “Superseded drawing revision in use on site; latest revision C04 not pulled into the work pack.” traced to DOC-MAR-MEP-203. Any other area built from the same superseded revision carries the same risk.
- Stone cladding mock-up outside agreed colour and coursing toleranceRoot cause “Material substitution proposed before compliance review gate was cleared.” traced to DOC-SQ-ARC-118. Any other area built from the same superseded revision carries the same risk.
Non-conformance register
Search by title or root cause; filter by severity or status.
Scenario
| Evidence chain | Party (fictional) | Captured in | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Cover to reinforcement below specification in localised areaNCR-RIVAGE-300Root cause: Workmanship supervision gap at shift change. | RIVAGE | low | verification | 15 Aug 2026 | AED 1.2m | 1 | — | Demo delivery partner A | Asite Field |
| Fire stopping incomplete at service penetrationNCR-PARK-FIVE-301Root cause: Sequence conflict between trades. | Park Five | low | open | 18 Aug 2026 | AED 263,415 | 1 | — | Demo MEP specialist D | Asite Field |
| Cover to reinforcement below specification in localised areaNCR-REGALIA-300Root cause: Workmanship supervision gap at shift change. | Regalia | low | open | 9 Aug 2026 | AED 1.6m | 5 | — | Demo delivery partner A | Asite Field |
| Fire stopping incomplete at service penetrationNCR-REGALIA-301Root cause: Sequence conflict between trades. | Regalia | low | corrective action | 4 Sept 2026 | AED 390,164 | 7 | — | Demo delivery partner B | Asite Field |
| Cover to reinforcement below specification in localised areaNCR-ELEVE-300Root cause: Workmanship supervision gap at shift change. | ELEVE | low | open | 16 Aug 2026 | AED 1.3m | 6 | — | Demo MEP specialist D | Asite Field |
| Fire stopping incomplete at service penetrationNCR-TALIA-301Root cause: Sequence conflict between trades. | Talia | low | closed | 4 Aug 2026 | AED 129,400 | 9 | — | Demo delivery partner A | Asite Field |
| Stone cladding mock-up outside agreed colour and coursing toleranceNCR-SQ-031Root cause: Material substitution proposed before compliance review gate was cleared. | Park Five | medium | open | 22 Sept 2026 | AED 1.9m | 14 | INS-SQ-0903 · DOC-SQ-ARC-118 | Demo fit-out specialist E | Asite Field |
| Fire stopping incomplete at service penetrationNCR-RIVAGE-301Root cause: Sequence conflict between trades. | RIVAGE | medium | closed | 3 Sept 2026 | AED 200,433 | 0 | — | Demo delivery partner B | Asite Field |
| Cover to reinforcement below specification in localised areaNCR-MAR-CASA-300Root cause: Workmanship supervision gap at shift change. | Mar Casa | medium | verification | 8 Aug 2026 | AED 946,048 | 12 | — | Demo delivery partner B | Asite Field |
| Fire stopping incomplete at service penetrationNCR-MAR-CASA-301Root cause: Sequence conflict between trades. | Mar Casa | medium | closed | 15 Sept 2026 | AED 1.2m | 9 | — | Demo delivery partner C | Asite Field |
22 of 22 illustrative records match. Export includes all filtered records.